Generator System | 30,000 Gallon Above Ground Fuel Storage Tank & Polishing System

SKU: GFLEET30

G-Fleet 30 | Above Ground Fuel Storage Tank & Polishing System
  • 30,000 Gallon Capacity
  • Support Multiple Generators From One Tank System
  • Fuel Polishing System
  • Fuel Transfer Management System
  • Download Drawings (Basic configuration Fireguard)
  • Download Specification Sheet
  • Download Turn-Key Brochure
  • Description
  • System Maintenance
  • AXI Fuel Polishing
  • Fire Rating Options

Description

Envirosafe’s Generator Systems are designed specifically to supply generator or boilers. The Envirosafe generator fuel tank is fully compatible with a wide range of fuels. Our generator fuel tanks are available in either Flameshield (UL-142) or Fireguard (UL-2085) configurations and can be manufactured as a single tank or in split designs for the supply of two different fuel products. Each system we sell is built in our on-site manufacturing facility and is fabricated in accordance with The Steel Tank Institute’s specifications as well as meeting all UL standards.

System Maintenance

Generator Tank & System Maintenance

The tank operator should preform periodic walk-around inspections to identify and repair areas of damage to the vessel or the coating itself and check for proper drainage around the tank area. It is imperative that the tank exterior be inspected periodically to ensure that the integrity of the coating is maintained. The frequency of periodic repainting will be based upon environmental factors in the geographic area where the tank is located. Special consideration should be given to the selected of the paint, surface preparation and coating application. The coating selected should be suitable for use with the current coating, or the existing coating should ne removed. The coating selected should be of industrial quality Proper site preparation and maintenance are vital to ensure drainage of surface water. Should ground conditions change or settlement occur, take the appropriate steps to maintain proper drainage and prevent standing water near or under the tank area. For diked tanks, remove any product spills immediately. Be sure to dispose of hazardous material properly. For diked tanks fitted with a drain, drain off water only. Drain openings are required to be maintained liquid tight. The primary tank shall be inspected monthly for the presence of water at the lowest possible points inside the primary tank. Remove any water found. Water and sediment in fuel can cause plugging of filters. Also, bacterial growth, originating form the fuel can cause corrosion of tanks and lines. For procedures on how to check for the presence of water and removal of water, refer to the STI R111, Storage Tank Maintenance/For copies of the RP and more information, please go to www.steeltank.com. Failure to adhere with these maintenance instructions may void your warranty.

Tank relocation requirements – often aboveground storage tanks are relocated. The following instructions are to be followed when this occurs: All steps are to be documented and the documentation is to be kept for the life of the tank. The hazards associated with the cleaning, entry, inspection, testing, maintenance or other aspects of AST’s are significant. Safety considerations and controls should be established prior to undertaking physical activities associated with ASTs . Cleaning of tanks must be per state and local jurisdiction requirements. Refer to the STI Standard SP001, “Standard for the Inspection of Aboveground Storage Tanks” for requirements concerning tank inspections. The SP001 Standard details requirements for inspections based on the tank installation and age. A tank must undergo the appropriate insurance prior to relocation. In addition, the tank must be subjected to a pressure (or vacuum) test.

Fire Rating Options

Fireguard Benefits

  • Tested Four-Hour Fire Resistance
  • UL 2080 Listed “Fire Resistant”
  • UL 2085 Listed “Protected”
  • Both Inner & Outer Steel Tanks built to UL Standards
  • Uniform Fire Code UFC “Protected” Tank
  • National Fire Protection (NFPA) 30 & 30A
  • International Fire Code (IFC)
  • Ballistics Protection
  • Impact protection
  • California Air Resources Board (CARB) for Air Emissions
  • Steel Tank Institute (STI) Standard F941 for Thermally Insulated Aboveground Storage Tanks

Flameshield Benefits

  • Tested Two-Hour Fire Resistance
  • Built to UL 142 Standards
  • Tested by Southwest Research Institute to SwRI 97-04
  • Double-Wall Tanks Have Fully Monitor-able Interstitial Space for Leak detection