Private Fleet Aviation Fueling Systems

02 / YOUR AIRCRAFT FLEET

Fuel your aircraft fleet. Track who uses what.

A dedicated fueling system gives your business a fixed point for storing and dispensing aviation fuel to its own aircraft. Match the dispensing package to your fleet, and choose the access and reporting tools your team needs.

A good fit when

A business or organization fuels its own aircraft and needs controlled access and internal fuel-use records.

Private Aviation Fleet system configuration
Representative configuration. Select the image to inspect it at full size.

WHAT MATTERS IN DAILY USE

Keep fueling aligned with your flight schedule.

A business fleet or flight school needs dependable access to the right fuel, practical turnaround between flights and a clear record of consumption. The useful configuration depends on the aircraft and the people doing the fueling—not simply the size of the organization.

Design around the fleet's actual fueling routine

Match the receiving connection, hose arrangement and required transfer time to the aircraft using the station. The supplied AvGas Option 1 example specifies a 50-foot hose, reel, swivel and breakaway; its usefulness depends on parking orientation and the operator's working position.

Pilot and line-team priority: a repeatable fueling position.

Know which aircraft received the fuel

The documented AvGas meter has a 100:1 pulse output. A compatible access and recording system can use that signal, but the meter alone does not identify the pilot, aircraft or department. Specify those records and the authorization method separately.

Fleet-manager priority: useful fuel-use accountability.

Make routine care practical

The AvGas drawings group equipment in a lockable cabinet with a roll-up door and include a filter differential-pressure gauge. The alternative package adds a moisture hand pump. Leave room to use and service those components; confirm the current filter element and operating instructions.

Maintenance priority: inspection access and a defined service package.

A private fleet can need more than one fueling arrangement.

Aircraft that cannot reach a fixed tank may need fuel delivered through a remote dispenser or refueler truck. An operation can also combine an employee-only station with public self-service. Define each fuel path and access model independently.

The same system serves different responsibilities.

For pilots and fleet staff

Explain the operating sequence, hose and connection choices, and how fuel use is attributed. Private access does not mean every user is a trained fueling technician.

For flight operations

Compare peak demand and supplier deliveries with usable inventory. Decide how operations continue while equipment is being inspected or serviced.

For facilities and maintenance

Confirm cabinet clearances, exact pump power, filtration, sampling and access controls. Keep the equipment included in the quote distinct from future options.

Starting from scratch? Compare the aircraft locations and daily fueling pattern. Expanding an existing station? Establish whether the constraint is storage, dispensing speed, operator access or downtime before choosing the addition.

Fuel destination
Storage → your fleet’s aircraft
Connection
Primarily overwing; underwing options by project
Access
Authorized users and aircraft-level usage tracking

FEATURES FROM THE SYSTEM DRAWINGS

Inside the documented AvGas cabinet configurations

The supplied 12,000-gallon Fireguard AvGas drawings show a protected dispensing cabinet and two different hose packages. The features below come from those BOMs, with the alternative configuration kept separate.

Fueling equipment inside a lockable cabinet

The welded fill box is specified with a drainage-shaped floor, vent and drain valve, plus a ROM door. It brings the fill and dispensing equipment into one protected, serviceable enclosure.

Fuel-use measurement ready for integration

A TCS SP 682-15 piston meter with a 100:1 pulser measures dispensed volume and provides an output that can be incorporated into compatible fuel-use tracking.

A filter-condition reading at the system

The historical drawing lists a Velcon VF-61 housing, Aquacon elements and a differential-pressure gauge. The gauge supports local filter-condition checks. Confirm the current element, fuel/additive compatibility and applicable operating requirements before selecting this package; the historical element is not a current recommendation.

A defined AvGas fill connection

The BOM includes a 3-inch overfill-prevention valve with diffuser and a 4-by-3-inch vapor-recovery adapter with cap. These make the delivery interface part of the equipment scope.

Separate fuel-level and leak indications

A 918 clock gauge with alarm box reports tank level; an interstitial leak gauge monitors the containment space. They serve different inspection needs.

A compact submersible pumping arrangement

The drawing specifies an FE Petro ¾-HP submersible pump on 240 V single-phase power. This is a specific electrical configuration, not a requirement inferred from tank size alone.

A hose package you can distinguish before ordering

The February drawing specifies a V820 reel with an AvGas nozzle and swivel. Its hose-length description has inconsistent notation, so a length is not asserted here.

An alternative with sampling and breakaway equipment

The June Option 1 BOM explicitly lists a 1-inch × 50-foot AvGas hose, N800 reel with stainless steel internals, 48-inch jumper hose, nozzle, swivel and breakaway. It also adds a moisture hand pump.

Configuration details that matter

These are two documented configurations, not one combined standard package. Option 1 item 30 establishes the 50-foot hose; the February drawing’s ambiguous hose-length notation needs confirmation. Neither AvGas BOM lists a floating-suction assembly.

Drawing references for these features
  • Fueling equipment inside a lockable cabinet
    February 8, 2023 drawing · sheet 5 · BOM items 11, 31
  • Fuel-use measurement ready for integration
    February 8, 2023 drawing · sheet 5 · BOM items 18
  • A filter-condition reading at the system
    February 8, 2023 drawing · sheet 5 · BOM items 19
  • A defined AvGas fill connection
    February 8, 2023 drawing · sheet 5 · BOM items 12, 15
  • Separate fuel-level and leak indications
    February 8, 2023 drawing · sheet 5 · BOM items 16, 28
  • A compact submersible pumping arrangement
    February 8, 2023 drawing · sheet 5 · BOM items 17
  • A hose package you can distinguish before ordering
    February 8, 2023 drawing · sheet 5 · BOM items 29
  • An alternative with sampling and breakaway equipment
    June 1, 2023 drawing · sheet 5 · BOM items 30, 31
  • 12000 FG AVGAS SYSTEM.pdf
    February 8, 2023 · sheet 5
  • 12000 FG AVGAS TANK_OPTION1.pdf
    June 1, 2023 · sheet 5

EQUIPMENT & OPTIONS

Built around a protected dispensing cabinet

The illustrated private-fleet package brings filling and dispensing equipment into a welded steel enclosure attached to the tank. Specify the final equipment schedule with your quote.

Welded cabinet and ROM roll-up door
A lockable enclosure protects meters, reels, hoses and controls from exposure and provides access for service. Confirm clearances around the open cabinet and service platform.
TCS meter and air eliminator
Metering and pulse outputs support fuel-use records. Match the meter, fuel-management interface and calibration requirements to the application.
Hannay hose reel
Stainless steel aviation reels are offered with rewind arrangements suited to the hose. Published configurations include spring rewind for shorter 25-foot hoses and powered rewind for longer hoses.
Hose and overwing nozzle
The published package uses JGB hose and OPW overwing nozzles. Goodyear, ContiTech and Trelleborg hose options have also been offered; the quote establishes manufacturer, diameter, length and fuel compatibility.
Fill and overfill equipment
The published arrangement uses a 90% level alarm and 95% fill shutoff. Confirm the devices, setpoints, truck interface and any AvGas vapor-recovery requirements in the approved site design.
Floating suction and filtration
Floating suction draws above the tank bottom. Filtration and sampling provisions are selected for the fuel and operating requirements; they complement routine fuel-quality checks.
Built around a protected dispensing cabinet
Representative configuration. Select the image to inspect it at full size.

EQUIPMENT & OPTIONS

Match the flow and connection to your aircraft

Dispensing rate
Published private-fleet configurations offer preset rates from 15–50 GPM. Required nozzle pressure, hose length and aircraft limits determine the selected operating point.
Overwing and underwing
Overwing is the primary arrangement. Specify any underwing requirement and the exact aircraft connection before the system is configured.
Access and fuel management
Choose the required user authorization, aircraft identification, fuel-use reporting and level-monitoring functions. Retail payment is a separate requirement to discuss.

TANK & FUEL SELECTION

Aviation fuel tank options: UL 142 Flameshield and UL 2085 Fireguard

Specify the tank and the fuel together. The construction, the listing and each fuel grade’s equipment scope are decided as one package.

UL 142 double-wall / Flameshield

Discuss the double-wall construction and Flameshield option with the project team. Confirm the listing and installation requirements for the actual site.

UL 2085 Fireguard

Discuss a protected Fireguard tank when the project calls for this construction. The selected listing, clearances and site design must be reviewed together.

Each fuel has its own equipment scope

Identify Jet-A, AvGas and every additional grade separately. For Jet A-1, Jet B, SAF blends or military fuels such as JP-4, JP-5 or JP-8, request a review of the actual fuel specification, lining, seals, filtration and dispensing components.

BUILD YOUR PROJECT SCOPE

What should we know for your quote?

Start with what you know. Our team can help resolve the remaining design decisions.

  1. How many aircraft use the system, and what fuel grade and fueling connection does each require?
  2. What is normal daily consumption and the largest expected fueling event?
  3. Do you need user credentials, aircraft IDs, department billing or inventory reporting?
  4. What hose length, rewind method, nozzle and target flow are appropriate for your operating area?
  5. Is this a new installation, replacement, or additional system alongside existing equipment?
More than one system?

List each system separately, with its own fuel, capacity, dispensing destination and controls. A site can combine several of these applications.

Build, copy or print your installation scope

FROM FACTORY TO SITE

How an aviation fueling system is delivered

Factory integration. A defined installation scope. The three steps below apply to every application.

01 / Design the system

Define fuel grades, storage, connections, equipment and controls. The quote and approved drawings establish what is included and what remains site work.

02 / Manufacture and prepare

Envirosafe manufactures the tank and integrates the specified package. Plumbing, wiring and checks that can be completed without fuel are addressed at the factory.

03 / Install and commission

Coordinate permits, foundations, lifting, utilities, site connections and startup responsibilities. Commissioning and fuel-quality checks must be completed before operation.

Explore other aviation applications

Made in U.S.A. for over 30 years!

A Proud American Manufacturer for Over 30 YearsMADE IN U.S.A.

Contact Us

800-555-4754
info@envirosafetanks.com
1789 E CR 48, Bushnell, FL 33513

Headquarters, USA

1-800-555-4754