500 Gallon Fuel Tank | Turn-Key

SKU: ECUBE500FG-TK
Sale!

Original price was: $23,002.19.Current price is: $16,014.19.

500 Gallon Fuel Tank | Turn-key
  • 500 Gallon Fuel Tank (1,892L)
  • Above-Ground Fuel Storage Tank & Dispensing System
  • Complete & Turn-key (connect to power, add fuel, and your ready to go)
  • STI Fireguard® / UL2085 / NFPA 30 and 30a (can be used in any state including California)
  • Turn-key Fuel Tank Features:
    • 15, 20, or 35 gallons per minute pump (retail gas stations pump at 10gpm max)
    • 18′ x 3/4″ to 100′ x 1″ hose w/ retractable Hannay hose reel
    • 16″ man-way for easy tank maintenance and cleaning
    • 7.5 gallon rust-proof aluminum spill bucket
    • Fuel level gauge, emergency & standard vents included (meets all US state requirements), interstitial leak gauge
  • Ballistic resistant
  • Vehicle impact resistant
  • Survives brutal 4-hour 2000˚ furnace test
  • 30 year tank warranty backed by the Steel Tank Institute (STI)
Request Formal Quote or Call 800-555-4754

In stock

  • Description
  • Additional information
  • Features
  • Maintenance

Description

Our 500 Gallon Fuel Tank provides a reliable and secure solution for fuel management. Engineered to meet industry standards, these fuel storage tanks feature UL2085 Fireguard ratings, ensuring safety and compliance. Designed for aboveground installation, our fuel storage tanks are built from high-grade materials that resist corrosion and extend service life.

The robust construction of our 500 Gallon Fuel Storage Tanks guarantee dependable performance under various environmental conditions. Our tanks are optimized for storing gasoline, diesel, and alternative fuels, making them versatile for commercial, industrial, and residential applications. With a focus on efficient fuel management, these storage tanks minimize leak risks and maintain fuel quality.

Our aboveground fuel storage tanks incorporate essential safety features such as leak detection, secondary containment, and an easy-access design for regular maintenance and inspections. The UL2085 Fireguard rating underscores the tanks’ ability to withstand fire hazards, providing an extra layer of protection for your fuel storage system. Additionally, these tanks comply with strict environmental regulations, ensuring minimal impact on surrounding areas.

Installation of our 500 Gallon Fuel Tanks is streamlined for efficiency. Detailed instructions and support services are available, reducing downtime and maintenance costs. Whether used in remote locations or urban facilities, our fuel storage tanks are engineered for durability and safety. Choose our 500 Gallon Fuel Storage Tanks to enhance your fuel management strategy. Our tanks combine safety, performance, and reliability to deliver a long-lasting storage solution. Explore our product specifications and certifications for detailed information on how our fuel storage tanks can meet your operational needs. Contact our team today for technical support and installation guidance. Trust our proven track record in fuel storage solutions for your next project.

Our UL2085 Fireguard rated 500 gallon fuel tanks set industry benchmarks for efficiency, safety, and durability in modern fuel management solutions today.

See all of our entire family of small fuel storage tanks

Additional information

Weight 5100 lbs
Dimensions 90 × 95 × 95 in
Fire Rating:

Fireguard™ – UL2085

Features

500 Gallon Small Fuel Fleet System Features

(1) UL-2085 Fireguard Tank Mounted on Fork Lift Pockets

(2) 4” 8 Oz Emergency Vent Male w/O-ring

(1) 2” Stack Vent (12′ above grade)

(1) 5 Gal Overspill with Lockable Cap. EQ #726

(1) Kruger level gauge standard or optional 918 or 818 Clock Gauge w/ Standard Float

(1) Engineered Hurricane Tie Down

(1) Interstitial Leak Gauge

(1) Tank Decal Kit

(1) Envirolastic 940 DTM Polyaspartic Urethane for High Performance Finish

(1) Fill-Rite Hi-Vol 1” Assembly Digital Meter, 1” Auto Nozzle & 18′ x 1” Hose

(1) Overfill Valve

(1) Husky 1” Breakaway & Husky 1” Swivel

(1) Cim-Tek 1.5” Filter Adapter & 1″ Inlet/Outlet

(1) Bracket, Piping, Ball Valve & Anti-Syphon Valve

(1) 16” Man way for easy inner tank accessibility or optional 18″ Man way

(1) UL Labeled & Listed (Per your local Fire Marshall)

(1) Step ladder with Platform

(6) Replacement Fuel Filters

STEEL THICKNESS 3/16” SHELL & 1/4” HEAD

(1) Touch-up paint

* Unleaded System will come with a Vapor Lock Relief Valve

Fireguard Benefits

UL 2080 Listed “Fire Resistant”

UL 2085 Listed “Protected”

Both Inner & Outer Steel Tanks built to UL Standards

Uniform Fire Code UFC “Protected” Tank

National Fire Protection (NFPA) 30 & 30A

International Fire Code (IFC)

Ballistics Protection

Impact protection

California Air Resources Board (CARB) for Air Emissions

Steel Tank Institute (STI) Standard F941 for Thermally Insulated Aboveground Storage Tanks

Flameshield Benefits

Tested Two-Hour Fire Resistance

Built to UL 142 Standards

Tested by Southwest Research Institute to SwRI 97-04

Double-Wall Tanks Have Dedicated Interstitial Space for Leak detection

Maintenance

500 Gallon Fuel Tank Maintenance

The tank operator should preform periodic walk-around inspections to identify and repair areas of damage to the vessel or the coating itself and check for proper drainage around the tank area. It is imperative that the tank exterior be inspected periodically to ensure that the integrity of the coating is maintained. The frequency of periodic repainting will be based upon environmental factors in the geographic area where the tank is located. Special consideration should be given to the selected of the paint, surface preparation and coating application. The coating selected should be suitable for use with the current coating, or the existing coating should ne removed. The coating selected should be of industrial quality Proper site preparation and maintenance are vital to ensure drainage of surface water. Should ground conditions change or settlement occur, take the appropriate steps to maintain proper drainage and prevent standing water near or under the tank area. For diked tanks, remove any product spills immediately. Be sure to dispose of hazardous material properly. For diked tanks fitted with a drain, drain off water only. Drain openings are required to be maintained liquid tight. The primary tank shall be inspected monthly for the presence of water at the lowest possible points inside the primary tank. Remove any water found. Water and sediment in fuel can cause plugging of filters. Also, bacterial growth, originating form the fuel can cause corrosion of tanks and lines. For procedures on how to check for the presence of water and removal of water, refer to the STI R111, Storage Tank Maintenance/For copies of the RP and more information, please go to www.steeltank.com. Failure to adhere with these maintenance instructions may void your warranty.

Tank relocation requirements – often aboveground storage tanks are relocated. The following instructions are to be followed when this occurs: All steps are to be documented and the documentation is to be kept for the life of the tank. The hazards associated with the cleaning, entry, inspection, testing, maintenance or other aspects of AST’s are significant. Safety considerations and controls should be established prior to undertaking physical activities associated with ASTs . Cleaning of tanks must be per state and local jurisdiction requirements. Refer to the STI Standard SP001, “Standard for the Inspection of Aboveground Storage Tanks” for requirements concerning tank inspections. The SP001 Standard details requirements for inspections based on the tank installation and age. A tank must undergo the appropriate insurance prior to relocation. In addition, the tank must be subjected to a pressure (or vacuum) test.

Made in U.S.A. for over 30 years!

A Proud American Manufacturer for Over 30 YearsMADE IN U.S.A.

Contact Us

800-555-4754
info@envirosafetanks.com
1789 E CR 48, Bushnell, FL 33513

Headquarters, USA

1-800-555-4754